19
Unique Switch 55 - Printer
Switch
Initial
Setting
Adjust Usage/Comments
7 1
Factory use only
6 0
5 1
Limit of the memory capacity
in Reverse order print
F-320 Setting
Determine the limit of the memory capacity for
storing the received document in the reverse order
print. If the data reached to this limit during
receiving, the normal order print will start.
Switch 6 5
0 0 126 KB
0 1 521 KB
1 0 1024 KB
1 1 2048 KB
4 0
Ignore the size error with
bypass tray
0: No
1: Yes
If this switch is set “1”, the machine doesn’t detect
the paper mismatch error when using the bypass
tray.
3 0
Factory use only
2 0
Disable the printing margin
0: No (204 mm print)
1: Yes (210 mm print)
When this switch is set to “1”, the machine will not
mask the both side of the printed document.
Note: This switch is available only for European
version.
1 0
Factory use only
0 1
Primary copying upon
printing the received data
0: No
1: Yes
Setting to “1”, the copying job will interrupt the
printing job of received document.