4-9
Improper LED exposure
Replace the LED Print Head Unit.
Replace the Main Control PCB.
Improper charging
Replace the High Voltage Unit.
Replace the Main Control PCB.
4.11.3 Printout too light
Symptom: Printed image is faint or does not print solid.
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
Poor development
Remove the toner cartridge and shake it a few times to redistribute the toner inside. If the problem
persists, replace the toner cartridge.
Replace the High Voltage Unit.
Clean the LED print head.
Defective Drum
Replace the Drum Cartridge.
Poor image transfer
Replace the Image Transfer Unit.
Replace the High Voltage Unit.
Replace the Main Control PCB.
4.11.4 Printout too dark
Symptom: Printed image is faint or does not print solid.
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
Poor development
Remove the toner cartridge and shake it a few times to redistribute the toner inside. If the problem
Vista de pagina 164