12
Machine Parameter 92
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Printer registration
adjustment (Horizontal) at
the first cassette.
Adjusts the start point to
print.
The plus setting increase the
left margin and the minus
setting decrease it.
Each setting changes by
0.5 mm
Initial Setting T.B.D
Switch 76543210 Settings
00001000 4.0 mm Maximum
|
|
00000010 1.0 mm
00000001 0.5 mm
00000000 0.0 mm
10000001 -0.5 mm
10000010 -1.0 mm
10000011 -1.5 mm
10000100 -2.0 mm
10000101 -2.5 mm
10000110 -3.0 mm
10000111 -3.5 mm
10001000 -4.0 mm Minimum
Machine Parameter 93
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Printer registration
adjustment (Horizontal) at
the optional second cassette.
Adjusts the start point to
print.
The plus setting increase the
left margin and the minus
setting decrease it.
Each setting changes by
0.5 mm
Initial Setting T.B.D
Switch 76543210 Settings
00001000 4.0 mm Maximum
|
|
00000010 1.0 mm
00000001 0.5 mm
00000000 0.0 mm
10000001 -0.5 mm
10000010 -1.0 mm
10000011 -1.5 mm
10000100 -2.0 mm
10000101 -2.5 mm
10000110 -3.0 mm
10000111 -3.5 mm
10001000 -4.0 mm Minimum