Vista de pagina 115
3-91
Unique Switch 74 - Operation
Switch
Initial
Setting
Adjust Usage/Comments
7 0
Factory use only
6 0
Factory use only
5 0
Factory use only
4 0
Factory use only
3 0
Security reception after
printing Security Rx
document
0: Inactive
1: Active
When set to “1”, the security reception function
remains active even after printing the security
reception documents.
2 1
Factory use only
1 0
The transmission time on
TCR
0: Print
1: Blank
Determine if the transmission time will be printed on
the TCR.
0 1
Factory use only
Unique Switch 75 - Operation
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
1
1
0
0
1
Idle time until the machine
shifts to the sleep mode
The machine will automatically enter sleep mode
after the idle time has elapsed. The idle time can be
set by a user operation.