Muratec F-565 Especificaciones Pagina 160

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 383
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 159
3-76
Attribute 3 - Individual Autodialer Setting (Equivalent to Memory Switch 012)
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 0 Changing the date format of
the transmitted TTI
0: No
1: Yes
When set to “1”, the machine changes the date
format of the transmitted TTI from MM: DD: YY, or
vice versa.
4 1 TTI transmit
0: No
1: Yes
(Note: Turning TTI
transmission off may violate
local or federal regulations.)
When set at “0”, transmission of the TTI is disabled.
The TTI includes the followings:
• Sender name
• Sender’s fax number
• Data & time, and number of pages
To set the individually transmission of them, see
Memory SW 016.
3 0 ECM response time
0: 3 sec
1: 4.8 sec
The time limit to receive the response signal for the
ECM post message.
2 0 ECM error retransmit time
0: 200 ms
1: 400 ms
The time limit before the ECM error is retransmitted.
1 0 Interval between DIS and DCS
0 0 0 ms 500 ms 1000 ms 1500 ms
Switch 1 0 0 1 1
Switch 0 0 1 0 1
Vista de pagina 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 382 383

Comentarios a estos manuales

Sin comentarios