Memory Switch 065 — Remote reception
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Adjustment of CI detect time Sets the time added to or reduced from the CI
detect time.
Switch 7 6 5 4 3 Time
1 1 1 1 1 150 msec
1 1 1 0 1 140 msec
: :
0 1 0 0 1 40 msec
0 0 1 1 1 30 msec
0 0 1 0 1 20 msec
0 0 0 1 1 10 msec
0 0 0 0 0 0 msec Initial setting
0 0 0 1 0 -10 msec
0 0 1 0 0 -20 msec
0 0 1 1 0 -30 msec
0 1 0 0 0 -40 msec
: :
1 1 1 0 0 -140 msec
1 1 1 1 0 -150 msec
6 0
5 0
4 0
3 0
2 0 Factory use only
1 0 Factory use only
0 0 Beep if fax handset hang up
0: Yes
1: No
Determines if your machine beeps when having left
the fax’s handset hanging up after communication.
Memory Switch 066 ~ 069 — Factory use only