Muratec MFX-1330 Especificaciones Pagina 268

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 290
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 267
5-78
5-78
5.3.8 ADF zoom adjustment (Horizontal)
A
Note: This adjustment must be made after the adjustments of printer registration (top and side) of the 1st cassette have
been made.
The difference should be within ± 1.0 % of the actual length of A on the test chart No.2003-01. Adjust so that the
following specifications are satisfied with the length of A on the test chart No. 2003-01.
Zoom ratio Standard Adjustment Tool Setting Range
100 % ± 1.5 % Machine parameter:011
– 1.5 to 1.5 %
(0.1 % step)
Adjustment procedure
1. Load legal (for USA version) or A4 (for GBR version) size paper to the first cassette.
2. Place the Muratec Test Chart No. 2003-01 in the ADF.
3. Make two copies on paper in the 1st cassette with 100 % magnification.
4. Measure the length of A on the second copy to find the difference.
If length A falls outside the specified range, perform the following steps to make the adjustment.
5. Enter Machine Parameter mode. (Press MENU, *, 0, 0)
6. Adjust the setting of Machine Parameter 011 to meet the specification.
If the length A is shorter than the standard, increase value.
If the length A is longer than the standard, decrease value.